Professional RF Microneedle Beauty Device with Multi Level Energy Settings for Deep Skin Repair

Still deciding? Get samples of $ !
Request Sample

Product Description

RF Microneedling Skin Tightening Machine For Wrinkle Reduction And Collagen Regeneration Therapy
Professional RF Microneedle Beauty Device with Multi Level Energy Settings for Deep Skin Repair
Advanced Skin Rejuvenation Technology

The M8 combines microneedling and RF energy for powerful skin regeneration and tightening. The microneedles create controlled micro-injuries that stimulate tissue regeneration, while the RF energy promotes collagen remodeling, significantly enhancing skin firmness.

Common Applications:
  • Fine lines and wrinkles
  • Acne scars
  • Skin laxity and sagging
  • Uneven skin tone and texture
  • Stretch marks

M8 is versatile and can be used on various body areas, though it is most commonly applied for facial rejuvenation, making it an ideal choice for those seeking youthful skin.

Professional RF Microneedle Beauty Device with Multi Level Energy Settings for Deep Skin Repair
Professional RF Microneedle Beauty Device with Multi Level Energy Settings for Deep Skin Repair
Professional RF Microneedle Beauty Device with Multi Level Energy Settings for Deep Skin Repair
Professional RF Microneedle Beauty Device with Multi Level Energy Settings for Deep Skin Repair
Skin Concerns and Treatments
  1. Wrinkles: General wrinkles, Crow's feet, and Neck wrinkles.
  2. Facial Rejuvenation: Tightening and lifting treatments.
  3. Stretch Marks: Focused treatment options.
  4. Large Pores
  5. Dull Skin
  6. Skin Redness
  7. Skin Whitening
  8. Acne Scars
  9. Depressed Scars
  10. Routine Skin Care and Maintenance
Product Specifications
Technical & Basic Specifications
Product Name M8 fractional rf microneedle wrinkle removal machine
Application Salon, Home
Portable Yes (Portable)
Treatment Head/Tip Pins Nano, 12pin, 24pin, 40pin
Treatment Area Face and Body
Needle Thickness 0.3mm
Needle Depth 0.2 - 8mm (0.1 step)
Treatment Duration 0.1 ~ 0.6s
Cool Temperature Range -10 to -5 to 0
Hot Temperature 0 to 36 to 40
Handle Configuration 2 Handles (1 for Face, 1 for Body)
Voltage AC 110V/220V, 50Hz/60Hz
Transport Package Flight Case
HS Code 8543709990
Production Capacity 100
Professional RF Microneedle Beauty Device with Multi Level Energy Settings for Deep Skin Repair
Professional RF Microneedle Beauty Device with Multi Level Energy Settings for Deep Skin Repair
Post-Treatment Instructions
  1. Avoid Touching or Washing: Refrain from touching or washing the treatment area for 6 hours after your procedure to allow the micro-channels to close and minimize the risk of bacterial introduction. After 6 hours, gently cleanse your face with a mild facial wash.
  2. Soothing Masque: If your skin feels warm during the initial 6 hours, you may use a SkinCeuticals Biocellulose Masque to hydrate, cool, and soothe your skin. This is permissible as it comes in sterile packaging.
  3. Makeup and Sunscreen: After the 6-hour mark, you can apply makeup and sunscreen as needed. For optimal healing, use a gentle wound healing cream twice daily in the following days.
  4. Ongoing Care: Continue using a gentle cleanser and healing cream twice daily for 7-10 days post-treatment. It's normal to experience dryness, redness, and swelling, and there may be a risk of bruising.
  5. Avoid Excess Heat: For the remainder of the day, steer clear of excessive heat, strenuous exercise, and sun exposure.
  6. Skip Harsh Products: Avoid exfoliating agents, harsh acids, and retinols for about a week following your treatment.
  7. Sunscreen Protection: Always wear sunscreen and reapply frequently if you will be exposed to the sun for extended periods!
Frequently Asked Questions
How many sessions of RF are needed for stretch marks?
Typically, patients require 3 to 6 sessions, spaced about 4 to 6 weeks apart, depending on the severity of the stretch marks and the desired results.
How long after the treatment should I wait before washing my face?
You should avoid touching or washing the treated area for at least 6 hours after the procedure to allow the micro-channels to close properly. After 6 hours, you can gently cleanse your face with a mild facial wash.
What can I do if my skin feels warm immediately after treatment?
If your skin feels warm during the initial 6 hours post-treatment, you may apply a sterile SkinCeuticals Biocellulose Masque to help hydrate, cool, and soothe your skin.
What are the recommended post-treatment skin care routines?
Use a gentle cleanser and a healing cream twice daily for 7-10 days post-treatment. Avoid exfoliating agents, harsh acids, and retinols for about a week, and always wear sunscreen.
What kind of needles and depths does the M8 machine support?
The machine supports Nano, 12pin, 24pin, and 40pin tip configurations with an adjustable needle depth of 0.2mm to 8mm (adjustable in 0.1mm steps) and a needle thickness of 0.3mm.
Is the RF Microneedling machine portable and suitable for home use?
Yes, this machine is designed to be portable and is suitable for both professional salon environments and home usage.